Request a QuoteEngineered for Reliable Medium-Voltage Power Distribution
YIMENG 20kV / 22kV oil-immersed transformers are specified for medium-voltage power distribution projects, including utility substations, industrial facilities, renewable energy installations and infrastructure developments. Selecting the right voltage ratio and rated capacity helps match the transformer to the network, connected load and planned expansion.
For a 20kV distribution transformer or a 22kV oil transformer, the project specification should define secondary voltage, frequency, vector group and short-circuit impedance. ONAN cooling uses natural oil and air circulation to transfer heat. Copper or aluminum windings, tap arrangements and installation requirements can be reviewed to establish the appropriate configuration.
Transformer selection also involves no-load and load losses, insulation levels, temperature-rise limits, ambient conditions and site clearances. These values depend on the selected design and should be confirmed in the technical schedule. Indoor and outdoor installations require suitable arrangements for ventilation, access and oil containment.
Planning a new substation or upgrading an existing distribution system? Send YIMENG your required kVA rating, 20kV or 22kV primary voltage, secondary voltage, installation location and project requirements. Request a project-specific technical proposal and quotation for an oil-immersed distribution transformer configured for your application.
Natural Cooling
Project Configuration
Winding Options
Engineering Support
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Oil-immersed transformer |
| Rated Primary Voltage | 20 / 22kV / Customizable |
| Rated Capacity | 80kVA/ 200kVA/ 250kVA/ 500kVA/ 800kVA/ 1000kVA/ 1500kVA/ 2000kVA/ 2500kVA/ Customizable |
| Rated Secondary Voltage | 110V/ 220V/ 400V/ 415V/ 433V/ Customizable |
| Rated Frequency | 50 / 60 Hz |
| Number of Phases | 3 Phases |
| Vector Group | Dyn11/ Yyn0 |
| Cooling Method | ONAN |
| Tapping Range | ±2 × 2.5% or ±5% |
| Tap Changing Mode | On-Load Tap Changing (OLTC)/ No-Load Tap Changing (NLTC) |
| Standard | IEC 60076 / GB 1094 |
| Winding Material | Copper / Aluminum |
| Installation | Indoor / Outdoor |
| Short-Circuit Impedance(%) | Customizable |
| No-Load Loss(W) | Customizable |
| Load Loss(W) | Customizable |
| No-Load Current(%) | Customizable |
| Insulation Level(kV) | Customizable |
| Temperature Rise Limits(K) | Customizable |
| Insulating Liquid | Customizable |
| Overall Dimensions (L×W×H)(mm) | Customizable |
| Oil Mass(kg) | Customizable |
| Total Mass(kg) | Customizable |
| Applicable Standard() | Customizable |
Final configuration and technical values are subject to project confirmation. 1000 kVA = 1 MVA.