33kV / 35kV Dry-Type Transformers equipment

33kV / 35kV Dry-Type Transformers

Cast-resin solutions for medium-voltage projects.
Configured around your power requirements.

REQUEST A QUOTE

Engineered for Medium-Voltage Power Distribution

YIMENG 33kV / 35kV dry-type transformer solutions are configured for medium-voltage power distribution in industrial plants, commercial developments and infrastructure projects. Cast-resin insulation and a three-phase design provide an oil-free option for protected indoor electrical rooms. Specify the primary voltage, secondary voltage and rated capacity around your network and load requirements.

For a 33kV dry-type transformer or 35kV cast-resin transformer project, review natural-air (AN) or fan-assisted (AF) cooling, winding material, enclosure protection and temperature monitoring. The final configuration should account for load profile, installation altitude, ambient temperature, ventilation and maintenance access.

For coastal facilities and demanding industrial environments, include humidity, salt exposure and site protection requirements in the enquiry. Send your insulation coordination, impedance and loss requirements to support engineering review and a project-specific quotation.

Dry-Type Design

Air Cooling

Temperature Monitoring

Project Configuration

Technical Specifications

ParameterSpecification
Product TypeDry-type transformer (cast-resin insulation)
Primary Voltage33kV / 35kV — project configuration
Rated Capacity (kVA)Source options: 30 / 50 / 80 / 100 / 125 / 160 / 200 / 250 / 315 / 400 / 500 / 630 / 800 / 1000 / 1250 / 1600 / 2000 / 2500; confirm applicability
Secondary VoltageSource options: 0.4kV / 400V / 415V / 433V / Customizable
Frequency / Phases50 / 60Hz / Customizable; 3 phases
Vector GroupDyn11 / Yyn0; subject to design
Cooling MethodAN (Air Natural) / AF (Air Forced)
Tapping RangeTo be confirmed
Tap Changing ModeNLTC / OLTC; subject to configuration
Standards for ReviewIEC 60076-11 / GB/T 10228-2023
Winding MaterialCopper / Aluminum
Insulation ClassClass F / Class H
Installation / EnclosureIndoor; IP00 / IP20 / IP23 options
Short-Circuit ImpedanceSource options: 4% / 5% / 6%; confirm for 33/35kV design
No-Load Loss / Load LossProject-specific
No-Load CurrentProject-specific
Insulation Level (kV)Confirm for 33/35kV insulation coordination
Temperature Rise LimitsProject-specific
Temperature ControlPT100 / PTC + controller; confirm sensor scheme
Fan ConfigurationOptional forced-air cooling
Dimensions / Total MassProject-specific
Noise LevelTo be confirmed
Other RequirementsProject-specific

All 33/35kV configurations require engineering confirmation. Final configuration and technical values are subject to project confirmation.

Configurable for Your Project

Voltage Ratio

Capacity

Cooling

Enclosure

Monitoring

Applications

Residential Communities
Residential Communities

Medium-voltage supply planning for large residential developments, subject to network requirements and site design.

Coastal Facilities
Coastal Facilities

Protected indoor distribution for coastal facilities, with humidity and salt exposure assessed during specification.

Office Buildings
Office Buildings

Power distribution for business campuses, configured around building loads and monitoring requirements.

Industrial Plants
Industrial Plants

Project-specific power distribution for manufacturing facilities. Share process loads, operating duty and installation conditions.

Illustrative application scenarios. Coastal installations require suitable indoor environmental protection.

Discuss Your Dry-Type Transformer Project

Send your primary and secondary voltages, capacity, frequency, cooling preference, enclosure, altitude, ambient temperature, insulation coordination and required losses for configuration review.

Yimeng Shared Transformer Project RFQ