20kV / 22kV Dry-Type Transformers equipment

20kV / 22kV Dry-Type Transformers

Cast-resin power distribution.
Configured for your project.

REQUEST A QUOTE

Engineered for Medium-Voltage Power Distribution

YIMENG 20kV / 22kV dry-type transformers are specified for medium-voltage power distribution projects in residential communities, commercial buildings, industrial plants and infrastructure facilities. A cast-resin, three-phase configuration provides an oil-free transformer option for indoor electrical rooms. Select the voltage ratio, rated capacity and enclosure to match your project requirements.

Configure your 20kV to 400V or 22kV to 415V transformer around the required secondary voltage, load profile and installation conditions. Natural-air (AN) and fan-assisted (AF) cooling options can be reviewed together with copper or aluminum windings, temperature monitoring and access for maintenance.

For coastal facilities, humidity, salt exposure and room ventilation must be assessed during specification. Share the installation altitude, ambient temperature, required losses and insulation coordination so the engineering team can confirm a suitable configuration and quotation.

Dry-Type Design

Air Cooling

Temperature Monitoring

Project Configuration

Technical Specifications

ParameterSpecification
Product TypeDry-type transformer (cast-resin insulation)
Primary Voltage20kV / 22kV — project configuration
Rated Capacity (kVA)30 / 50 / 80 / 100 / 125 / 160 / 200 / 250 / 315 / 400 / 500 / 630 / 800 / 1000 / 1250 / 1600 / 2000 / 2500; subject to confirmation
Secondary Voltage0.4kV / 400V / 415V / 433V / Customizable
Frequency / Phases50 / 60Hz / Customizable; 3 phases
Vector GroupDyn11 / Yyn0
Cooling MethodAN (Air Natural) / AF (Air Forced)
Tapping RangeTo be confirmed
Tap Changing ModeNLTC / OLTC; subject to configuration
Standards for ConfirmationIEC 60076-11 / GB/T 10228-2023
Winding MaterialCopper / Aluminum
Insulation ClassClass F / Class H
Installation / EnclosureIndoor; IP00 (open type) / IP20 / IP23
Short-Circuit Impedance4% / 5% / 6% / Customizable; confirm for selected rating
No-Load Loss / Load LossCustomizable
No-Load CurrentCustomizable
Insulation Level (kV)To be confirmed for 20/22kV insulation coordination
Temperature Rise LimitsCustomizable
Temperature ControlPT100 / PTC thermistor + temperature controller; confirm sensor scheme
Fan ConfigurationOptional forced-air cooling
Dimensions / Total MassCustomizable
Noise LevelTo be confirmed
Other Applicable RequirementsProject-specific

All 20/22kV configurations require engineering confirmation. Final configuration and technical values are subject to project confirmation.

Configurable for Your Project

Voltage Ratio

Capacity

Cooling

Enclosure

Monitoring

Applications

Residential Communities
Residential Communities
Coastal Facilities
Coastal Facilities
Office Buildings
Office Buildings
Industrial Plants
Industrial Plants

Illustrative application scenarios. Coastal installations require suitable indoor environmental protection.

Discuss Your Dry-Type Transformer Project

Send your required primary and secondary voltages, rated capacity, frequency, cooling preference, enclosure, installation altitude and ambient temperature. Include loss requirements and applicable project standards for configuration review.

Yimeng Shared Transformer Project RFQ