10kV / 11kV Dry-Type Transformers
Air-cooled power distribution.
Configured for your project.
Engineered for Reliable Indoor Power Distribution
YIMENG 10kV / 11kV dry-type transformers provide a configurable solution for power distribution projects in residential communities, commercial buildings, industrial plants and infrastructure facilities. The cast-resin three-phase design uses high-quality insulation materials with an air-cooled structure, delivering reliable performance for indoor installations.
Natural-air (AN) and fan-assisted (AF) cooling configurations are available to suit different load requirements. Temperature monitoring, ventilation and access requirements should be reviewed as part of the project design to ensure safe and stable operation.
For projects in coastal areas or other environments with higher humidity or salt air exposure, site conditions, enclosure protection, insulation levels and temperature rise limits should be carefully evaluated. Please share your project requirements including rated capacity, voltage ratio, installation location and operating conditions, and YIMENG can provide a confirmed model configuration and quotation.
Dry-Type Design
Air Cooling
Temperature Monitoring
Project Configuration
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Type | Dry-type transformer (Cast Resin Insulation) |
| Rated Primary Voltage | 10 / 11kV / Customizable |
| Rated Capacity | 30kVA/ 50kVA/ 80kVA/ 100kVA/ 125kVA/ 160kVA/ 200kVA/ 250kVA/ 315kVA/ 400kVA/ 500kVA/ 630kVA/ 800kVA/ 1000kVA/ 1250kVA/ 1600kVA/ 2000kVA/ 2500kVA/ Customizable |
| Rated Secondary Voltage | 0.4kV / 400V / 415V / 433V / Customizable |
| Rated Frequency | 50 / 60 Hz / Customizable |
| Number of Phases | 3 Phases |
| Vector Group | Dyn11 / Yyn0 |
| Cooling Method | AN (Air Natural) / AF (Air Forced) |
| Tapping Range | ±2 × 2.5% or ±5% |
| Tap Changing Mode | No-Load Tap Changing (NLTC) / On-Load Tap Changing (OLTC) |
| Standard | IEC 60076-11 / GB/T 10228-2023 |
| Winding Material | Copper / Aluminum |
| Insulation Class | Class F / Class H |
| Installation | Indoor |
| Enclosure | IP00 (Open Type) / IP20 / IP23 |
| Short-Circuit Impedance(%) | 4% / 5% / 6% / Customizable |
| No-Load Loss(W) | Customizable |
| Load Loss(W) | Customizable |
| No-Load Current(%) | Customizable |
| Insulation Level(kV) | 28kV (Power Frequency, 1min) / 75kV (Lightning Impulse) / Customizable |
| Temperature Rise Limits(K) | Customizable |
| Temperature Control System | PT100 PTC Thermistor + Temperature Controller |
| Fan Configuration | Optional (Forced Air Cooling) |
| Overall Dimensions (L×W×H)(mm) | Customizable |
| Total Mass(kg) | Customizable |
| Noise Level(dB) | ≤55dB (AN) / ≤65dB (AF) / Customizable |
| Applicable Standard | Customizable |
Final configuration and technical values are subject to project confirmation. Noise limits, sensor scheme and selected rating combination must be confirmed for the project.
Configurable for Your Project
Voltage Ratio
Capacity
Cooling
Enclosure
Monitoring
Applications




Illustrative application scenarios. Coastal installations require suitable indoor environmental protection.
Discuss Your Dry-Type Transformer Project
Share your requirements with our engineering team.