10kV / 11kV Dry-Type Transformers equipment

10kV / 11kV Dry-Type Transformers

Air-cooled power distribution.
Configured for your project.

REQUEST A QUOTE

Engineered for Reliable Indoor Power Distribution

YIMENG 10kV / 11kV dry-type transformers provide a configurable solution for power distribution projects in residential communities, commercial buildings, industrial plants and infrastructure facilities. The cast-resin three-phase design uses high-quality insulation materials with an air-cooled structure, delivering reliable performance for indoor installations.

Natural-air (AN) and fan-assisted (AF) cooling configurations are available to suit different load requirements. Temperature monitoring, ventilation and access requirements should be reviewed as part of the project design to ensure safe and stable operation.

For projects in coastal areas or other environments with higher humidity or salt air exposure, site conditions, enclosure protection, insulation levels and temperature rise limits should be carefully evaluated. Please share your project requirements including rated capacity, voltage ratio, installation location and operating conditions, and YIMENG can provide a confirmed model configuration and quotation.

Dry-Type Design

Air Cooling

Temperature Monitoring

Project Configuration

Technical Specifications

ParameterSpecification
Product TypeDry-type transformer (Cast Resin Insulation)
Rated Primary Voltage10 / 11kV / Customizable
Rated Capacity30kVA/ 50kVA/ 80kVA/ 100kVA/ 125kVA/ 160kVA/ 200kVA/ 250kVA/ 315kVA/ 400kVA/ 500kVA/ 630kVA/ 800kVA/ 1000kVA/ 1250kVA/ 1600kVA/ 2000kVA/ 2500kVA/ Customizable
Rated Secondary Voltage0.4kV / 400V / 415V / 433V / Customizable
Rated Frequency50 / 60 Hz / Customizable
Number of Phases3 Phases
Vector GroupDyn11 / Yyn0
Cooling MethodAN (Air Natural) / AF (Air Forced)
Tapping Range±2 × 2.5% or ±5%
Tap Changing ModeNo-Load Tap Changing (NLTC) / On-Load Tap Changing (OLTC)
StandardIEC 60076-11 / GB/T 10228-2023
Winding MaterialCopper / Aluminum
Insulation ClassClass F / Class H
InstallationIndoor
EnclosureIP00 (Open Type) / IP20 / IP23
Short-Circuit Impedance(%)4% / 5% / 6% / Customizable
No-Load Loss(W)Customizable
Load Loss(W)Customizable
No-Load Current(%)Customizable
Insulation Level(kV)28kV (Power Frequency, 1min) / 75kV (Lightning Impulse) / Customizable
Temperature Rise Limits(K)Customizable
Temperature Control SystemPT100 PTC Thermistor + Temperature Controller
Fan ConfigurationOptional (Forced Air Cooling)
Overall Dimensions (L×W×H)(mm)Customizable
Total Mass(kg)Customizable
Noise Level(dB)≤55dB (AN) / ≤65dB (AF) / Customizable
Applicable StandardCustomizable

Final configuration and technical values are subject to project confirmation. Noise limits, sensor scheme and selected rating combination must be confirmed for the project.

Configurable for Your Project

Voltage Ratio

Capacity

Cooling

Enclosure

Monitoring

Applications

Residential Communities
Residential Communities
Coastal Facilities
Coastal Facilities
Office Buildings
Office Buildings
Industrial Plants
Industrial Plants

Illustrative application scenarios. Coastal installations require suitable indoor environmental protection.

Discuss Your Dry-Type Transformer Project

Share your requirements with our engineering team.

Yimeng Shared Transformer Project RFQ