33kV / 35kV Oil-Immersed Transformers

REQUEST A QUOTE

Engineered for Reliable Medium-Voltage Power Distribution

YIMENG 33kV / 35kV oil-immersed transformers are intended for project-specific power distribution applications in utility substations, industrial plants, renewable energy facilities and infrastructure networks. A carefully specified transformer connects the incoming network voltage to the voltage required by downstream equipment, with capacity selected around the load profile and future expansion.

When specifying a 33kV oil transformer or a 35kV distribution transformer, define the primary and secondary voltages, rated capacity, frequency and vector group. Cooling method, winding material and tap-changing arrangements should be reviewed together with the operating conditions. ONAN cooling uses natural oil and air circulation; the final cooling configuration depends on the selected design.

Insulation coordination is an important part of transformer selection for 33kV and 35kV networks. The highest voltage for equipment, power-frequency withstand voltage and lightning impulse withstand level must be agreed for the project. Short-circuit impedance, no-load and load losses, temperature-rise limits and protection requirements should also be documented in the technical specification.

For outdoor substations or indoor installations, provide the site altitude, ambient temperature, available space and installation requirements. Send YIMENG your voltage ratio, kVA or MVA rating, application and delivery requirements to request a tailored technical proposal. Final dimensions, oil quantity, mass and guaranteed performance values are confirmed for the selected transformer.

Natural Cooling

Project Configuration

Winding Options

Engineering Support

Technical Specifications

ParameterSpecification
Product TypeOil-immersed transformer
Rated Primary Voltage33 / 35kV / Customizable
Rated Capacity80kVA/ 200kVA/ 250kVA/ 500kVA/ 800kVA/ 1000kVA/ 1500kVA/ 2000kVA/ 2500kVA/ Customizable
Rated Secondary Voltage110V/ 220V/ 400V/ 415V/ 433V/ Customizable
Rated Frequency50 / 60 Hz
Number of Phases3
Vector GroupDyn11/ Yyn0
Cooling MethodONAN
Tapping Range±2 × 2.5% or ±5%
Tap Changing ModeOn-Load Tap Changing (OLTC)/
No-Load Tap Changing (NLTC)
StandardIEC 60076 / GB 1094
Winding MaterialCopper / Aluminum
InstallationIndoor / Outdoor
Short-Circuit Impedance(%)Customizable
No-Load Loss(W)Customizable
Load Loss(W)Customizable
No-Load Current(%)Customizable
Insulation Level(kV)Customizable
Temperature Rise Limits(K)Customizable
Insulating LiquidCustomizable
Overall Dimensions (L×W×H)(mm)Customizable
Oil Mass(kg)Customizable
Total Mass(kg)Customizable
Applicable Standard()Customizable

Final configuration and technical values are subject to project confirmation. 1000 kVA = 1 MVA.

Configurable for Your Project

Voltage Ratio

Capacity

Winding Material

Installation

Protection

Applications

Utility Distribution
Utility Distribution
Industrial Facilities
Industrial Facilities
Renewable Energy
Renewable Energy
Infrastructure Projects
Infrastructure Projects

Discuss Your Transformer Project

Share your requirements with our engineering team.

Yimeng Shared Transformer Project RFQ