Ring Main Unit (RMU) — original website banner

Ring Main Unit (RMU)

Compact Medium-Voltage Switchgear for Distribution Networks

Request a Quote

Product Overview

YIMENG Ring Main Unit (RMU) provides switching, isolation and protection for medium-voltage distribution networks. It is suitable for ring-network and radial distribution arrangements serving compact substations, industrial facilities, commercial developments and renewable energy projects.

The product range covers 12 kV, 24 kV and 36 / 40.5 kV classes, with rated current options of 630 A and 1,250 A depending on the selected configuration. Functional units can be combined around incoming supplies, outgoing cables and transformer feeders, while manual or motorized operating mechanisms support different site operating requirements.

Key Features

Compact arrangement for distribution rooms and compact substations

Functional configurations for cable switching and transformer protection

Voltage classes covering 12 kV, 24 kV and 36 / 40.5 kV

Rated current options of 630 A and 1,250 A

Manual or motorized operating mechanisms

Insulation options subject to the selected model

Technical Specifications

ParameterUnit12 kV Class24 kV Class36 / 40.5 kV Class
Rated voltagekV122436 / 40.5
Rated frequencyHz50 / 6050 / 6050 / 60
Rated currentA630 / 1,250630 / 1,250630 / 1,250
Busbar rated currentA630 / 1,250630 / 1,250630 / 1,250
Rated short-time withstand currentkA20 / 2520 / 2520 / 25 / 31.5
Rated short-time withstand durations3 / 43 / 43 / 4
Rated peak withstand currentkA50 / 6350 / 6350 / 63 / 80
Rated short-circuit breaking current*kA20 / 2520 / 2520 / 25 / 31.5
Power-frequency withstand voltagekV28 / 4250 / 6570 / 95
Lightning impulse withstand voltagekV75 / 95125170 / 185
Insulation medium options**—SF₆ / Air / Eco-gasSF₆ / Air / Eco-gasSF₆ / Air / Eco-gas
Interruption medium options**—Vacuum / GasVacuum / GasVacuum / Gas
Protection ratings listed***—IP4X / IP67IP4X / IP67IP4X / IP67
Operating mechanism—Manual / MotorizedManual / MotorizedManual / Motorized
Installation location—IndoorIndoorIndoor
Reference altitudem≤ 1,000≤ 1,000≤ 1,000
Ambient temperature°C−25 to +40−25 to +40−25 to +40

Short-circuit breaking ratings apply to the relevant circuit-breaker functional unit, not automatically to load-break switch units.

Insulation and interruption media depend on the selected equipment design. Availability must be confirmed for the required voltage class and functional unit.

The applicable protection rating for the outer enclosure, sealed tank or individual compartment must be confirmed separately. IP67 is not stated as the protection rating of the complete assembly.

The table summarizes the supplied product-range information. Rating combinations, insulation test conditions and applicable IEC 62271 requirements are subject to the approved technical documentation.

Product Advantages

Compact Layout for Space-Constrained Installations

The compact arrangement helps accommodate medium-voltage switching functions within electrical rooms and compact substations. Final panel dimensions, cable-bending space and maintenance clearances are considered together during layout planning.

Functional Units Matched to the Distribution Scheme

Cable switch, switch-fuse and circuit-breaker functions can be specified according to the available product configuration. This allows the RMU arrangement to follow the project’s incoming, outgoing and transformer-feeder requirements.

Transformer Protection to Suit the Application

Transformer feeders can use an appropriate switch-fuse arrangement or a circuit breaker with protection relays, depending on the selected model. The protection method is chosen around transformer ratings, fault levels and coordination with upstream and downstream devices.

Switching and Isolation for Network Operation

Switching, isolation and earthing functions support planned network operation and maintenance. Interlocking arrangements help control the operating sequence, with the final functions confirmed for the selected configuration.

Manual or Motorized Operation

Manual mechanisms suit local operating requirements, while motorized options can support electrical operation. Remote control, status indication and communication interfaces can be reviewed where required by the project.

Enclosed Primary Equipment

For gas-insulated configurations, primary equipment is housed within a sealed tank, reducing direct exposure to the surrounding environment. Inspection and maintenance requirements remain specific to the supplied tank, operating mechanisms, cable connections and protection devices.

Typical Applications

Utility Distribution Networks

Cable switching, sectionalizing and transformer-feeder protection in suitable ring or radial distribution networks.

Compact Substations

Medium-voltage switching and protection within compact substations supplying residential developments, commercial facilities and public infrastructure.

Industrial Parks and Commercial Developments

Distribution to local transformers and feeder circuits, with functional units selected around site loads and operating requirements.

Renewable Energy Projects

Switching and protection for suitable wind and solar distribution circuits, subject to the required voltage class, current ratings and grid-connection design.

Discuss Your RMU Configuration

Send us your single-line diagram, required number of ways or project specifications so we can review a suitable RMU arrangement.

For an initial enquiry, please provide:

  • System voltage and rated frequency
  • Rated current and prospective short-circuit current
  • Required number of ways and function of each way
  • Transformer capacity and preferred protection method
  • Required short-time withstand duration
  • Preferred insulation medium, if specified
  • Manual, motorized or remote-control requirements
  • Cable sizes, quantities and connection requirements
  • Installation space, altitude and ambient conditions
  • Required quantity and project specifications

Final functional-unit combinations, dimensions, protection settings and accessories will be confirmed against the project requirements.

Request a Quote

Share your project requirements for configuration review.

Yimeng Global RFQ