KYN61 Metal-Clad Withdrawable Switchgear — original website banner

KYN61 Metal-Clad Withdrawable Switchgear

40.5 kV Switchgear for 35 kV Power Distribution Systems

Request a Quote

Product Overview

KYN61 metal-clad withdrawable switchgear is designed for indoor 35 kV power distribution systems, with an equipment rated voltage of 40.5 kV. It provides switching, control, protection and monitoring for incoming supplies, outgoing feeders and transformer circuits in substations, industrial facilities and renewable energy projects.

A withdrawable vacuum circuit breaker supports testing and servicing, while separate busbar, circuit-breaker, cable and low-voltage compartments provide an organized internal arrangement. Rated current options of 1,250 A, 1,600 A and 2,000 A allow equipment selection around project loads, with cabinet functions and protection schemes configured to suit the approved distribution design.

Key Features

Rated voltage of 40.5 kV for suitable 35 kV systems

Rated current options of 1,250 A, 1,600 A and 2,000 A

Withdrawable vacuum circuit breaker for testing and servicing

Separate compartments for primary equipment and secondary controls

Mechanical and electrical safety interlocks

IP3X enclosure protection for indoor installation

Technical Specifications

ParameterUnitSpecification
Model—KYN61
Product type—Metal-clad withdrawable switchgear
Installation location—Indoor
Rated voltagekV40.5
Rated frequencyHz50
Rated currentA1,250 / 1,600 / 2,000
Rated short-time withstand currentkA20 / 25 / 31.5
Rated short-circuit breaking currentkA20 / 25 / 31.5
Rated short-circuit making current — peakkA50 / 63 / 80
1-minute power-frequency withstand voltagekV95
Lightning impulse withstand voltage — full wavekV185
Enclosure protection rating—IP3X
Circuit-breaker type—Vacuum circuit breaker
Circuit-breaker arrangement—Withdrawable truck
Reference cabinet dimensions*mm1,400 × 2,800 × 2,600

Dimension order and final cabinet dimensions must be confirmed against the approved general arrangement drawing.

Current and short-circuit ratings are configuration-dependent. The applicable rating combination, short-time withstand duration and insulation test conditions will be confirmed in the final technical documentation.

Product Advantages

Designed for 35 kV Distribution Applications

With a rated voltage of 40.5 kV, KYN61 supports suitable 35 kV distribution circuits. Its specified power-frequency and lightning impulse withstand levels provide reference values for insulation selection alongside the project’s operating and site conditions.

Withdrawable Circuit Breaker for Planned Maintenance

The vacuum circuit breaker is mounted on a withdrawable truck, allowing movement between defined operating and test or disconnected positions. This arrangement supports functional testing and removal for servicing after the required isolation and safety procedures have been completed.

Separate Compartments for Organized Access

Dedicated busbar, circuit-breaker, cable and low-voltage compartments separate the main functional areas. Protection relays, instruments and control devices are arranged in the low-voltage compartment, supporting clear secondary wiring and convenient routine inspection.

Interlocks to Support Correct Operation

Mechanical and electrical interlocks help control the operating sequence between the circuit breaker, withdrawable truck and earthing equipment. The final interlocking scheme is selected to help prevent incompatible operations and is confirmed during project design.

Flexible Cabinet Functions

Incoming feeders, outgoing feeders, bus-section, metering and voltage-transformer functions can be incorporated into the lineup according to the approved single-line diagram. Transformer-feeder arrangements can also be specified to suit the distribution system.

Layout Planning for Installation and Expansion

Cabinet sections can be arranged to suit the required circuit quantities and switchroom layout. Cable access, maintenance clearances, equipment handling routes and potential future extensions can be considered during the design stage.

Typical Applications

Regional and Utility Substations

Incoming supply, transformer-feeder and bus-section circuits in suitable 35 kV substations. Metering and voltage-transformer panels can be included according to the station design.

Large Industrial Facilities

Power reception and distribution for steelworks, metallurgical plants, chemical parks and other facilities supplied at 35 kV. Transformer feeders connect to downstream transformers serving the plant’s distribution network.

Wind and Solar Power Projects

Switching and protection for suitable 35 kV collector circuits and substation feeders. Equipment selection takes account of the project’s current ratings, fault levels and protection requirements.

Transport and Major Infrastructure

35 kV distribution in railway and metro power facilities, ports, airports and water infrastructure, where the system ratings and installation conditions match the selected assembly.

Large Data Centre Power Systems

Incoming and transformer-feeder distribution for facilities using a 35 kV supply. Supply continuity is determined by the overall system architecture, including redundancy, backup power and protection coordination.

Discuss Your KYN61 Switchgear Requirements

Send us your single-line diagram, equipment schedule or project specifications so we can review a suitable switchgear arrangement.

For an initial enquiry, please provide:

  • Nominal system voltage and required equipment rated voltage
  • Rated frequency and circuit current requirements
  • Required short-circuit breaking current and withstand duration
  • Cabinet functions and number of panels
  • Protection, metering and local or remote control requirements
  • Cable sizes, quantities and entry arrangements
  • Switchroom dimensions and equipment access requirements
  • Site altitude, ambient temperature and humidity conditions
  • Preferred circuit-breaker and protection-relay brands, if applicable

Final cabinet dimensions, component selection, interlocking arrangements and accessories will be confirmed against the project requirements.

Request a Quote

Share your project requirements for configuration review.

Yimeng Global RFQ